Huawei S5720-28X-SI-AC

15814117 UZS

Huawei S5720-SI switches are flexible Gigabit Ethernet switches that deliver reliable, high-density Layer 3 switching for data centers. They support endpoints, video conferencing, and high-definition video surveillance applications. Featuring 10 Gbps uplink ports, IPv6 forwarding, and intelligent stacking (iStack) technology, these switches serve as aggregation switches in enterprise campus networks.

Category:
Description

Description

Huawei S5720-SI – flexible Gigabit Ethernet switches providing reliable, high-density Layer 3 switching for data centers. They support endpoints, video conferencing applications, and high-definition video surveillance. With 10 Gbps uplink ports, IPv6 forwarding, and intelligent stacking (iStack) technology, these devices function as aggregation switches in Corporate campus networks.

 

Memory (RAM) 512 MB
Flash Total 512 MB. To view the available flash memory size, run the command display version .
Mean Time Between Failures (MTBF) 82.4 years
Mean Time to Repair (MTTR) 2 hours
Availability > 0,99999
Service Port Overvoltage Protection Common Mode: ±6 kV
Power Supply Overvoltage Protection
  • Using AC Power Modules: ±6 kV differential mode, ±6 kV common mode.
  • Using DC power modules: ±1 kV differential mode, ±2 kV common mode.
Dimensions (H x W x D)
  • Main dimensions (excluding protrusions from the chassis): 44.4 x 442.0 x 424.7 mm (1.75 x 17.4 x 16.72 in)
  • Maximum dimensions (depth is the distance from the front panel ports to the rear panel handle): 44.4 x 442.0 x 451.8 mm (1.75 x 17.4 x 17.79 in)
Weight (with packaging) 9.1 kg (20.06 lb)
Stacking ports GE electrical ports and 10GE SFP+ optical ports, excluding the front panel combo ports.
RTK Supported
RPS Not supported
PoE Not supported
Nominal Voltage Range 100 VAC to 240 VAC, 50/60 Hz

-48 VDC to -60 VDC

Maximum Voltage Range 90 VAC to 264 VAC, 47 to 63 Hz

-36 VDC to -72 VDC

Maximum Power Consumption (100% Throughput, Full Fan Speed) 37.5 W

Typical Power Consumption (30% Transport load)

  • Tested according to ATIS standard.
  • EEE enabled
  • No PoE power consumption
22.3W
Operating Temperature 0°C to 45°C (32°F to 113°F) at 0–1,800 m (0–5,906 ft)

NOTE:

At 1,800–5,000 m (5,906–16,404 ft) altitude, the maximum operating temperature decreases by 1°C (1.8°F) for every 220 m (722 ft) increase in altitude.

Short-Term Operating Temperature -5°C to +50°C (23°F to 122°F) at 0–1800 m (0–5906 ft)

NOTE:

At 1,800–5,000 m (5,906–16,404 ft) altitude, the maximum operating temperature decreases by 1°C (1.8°F) for every 220 m (722 ft) increase in altitude.

The equipment may be operated outside the normal operating temperature range for short periods of time, but the following conditions must be met:

  • The equipment is operated above 45°C (113°F) for no more than 96 consecutive hours per year.
  • The equipment is operated above 45°C (113°F) for a total of no more than 360 hours per year.
  • The equipment is operated above 45°C (113°F) no more than 15 times per year.

The equipment may be damaged or experience unexpected behavior if any of the previous limits are exceeded.

The equipment cannot start at temperatures below 0°C (32°F). The maximum distance of optical modules used under these conditions cannot exceed 10 km.

Temperature Storage -40°C to +70°C (-40°F to +158°F)
Noise at normal temperature (27°C, sound power) < 52 dB(A)
Relative Humidity 5% to 95%, non-condensing
Operating Altitude
  • AC Power Module Configuration: 0–5000 m (0–16,404 ft)
  • DC Power Module Configuration: 0–2000 m (0–6,562 ft)
Certification
  • EMC Certification
  • Safety Certification
  • Production Certification
Additional information

Additional information

Бренд

Huawei

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Huawei S5720-28X-SI-AC”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat net

Vestibulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat netus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac vestibulum amet elit